Routing the Cables: 7357 R6LN Plus

To route the Tri-Light/Lane Light Cable and the LAN Cable in the 7357 unit, follow these steps:

  1. Route the Tri-Light/Lane Light Cable by doing the following:
    1. From the Tri-Light/Lane Light Pole, route the cable at the rear of the unit down the cable access hole and into the Core Cabinet, as shown in the image below. Use a cable tie to secure the cable to the vent.
      Note

      Apply enough cable slack to prevent the cable from being stretched during installation or removal procedures.

    2. Connect the cable to the Tri-Light port of the I/O Box, as shown in the image below.
    3. Secure the cable to the lance bridges using cable ties.

  2. Route the LAN Cable. Depending on the unit configuration, refer to the following:

No-Bag Unit: 7357 R6LN Plus

To route the LAN Cable, follow these steps:

  1. From the Tri-Light/Lane Light Pole, route the cable down the rear of the Core Cabinet and out through the side cable exit hole. Use a cable tie to secure the cable to the vent.
    Note

    Ensure that there is enough cable slack to avoid cables from being stretched during installation or removal procedures.

    Note

    The LAN Cable can exit either through the left or the right side cable exit hole depending on the customer's preference.

  2. Connect the cable to the PoE Switch.

Left-Hand Unit: 7357 R6LN Plus

To route the LAN Cable, follow these steps:

  1. From the Tri-Light/Lane Light Pole, route the cable down the rear of the Core Cabinet. Use a cable tie to secure the cable to the vent.
    Note

    Ensure that there is enough cable slack to avoid cables from being stretched during installation or removal procedures.

  2. Continue to route the cable through the left side cable exit hole and into the Bagwell.
  3. Pass the cable through the bottom cable exit hole of the Bagwell.

  4. Connect the cable to the PoE Switch.

Right-Hand Unit: 7357 R6LN Plus

To route the LAN Cable, follow these steps:

  1. From the Tri-Light/Lane Light Pole, route the cable down the rear of the Core Cabinet. Use a cable tie to secure the cable to the vent.
    Note

    Ensure that there is enough cable slack to avoid cables from being stretched during installation or removal procedures.

  2. Continue to route the cable out through the right side cable exit hole and into the Bagwell.
  3. Pass the cable through the bottom cable exit hole of the Bagwell.

  4. Connect the cable to the PoE Switch.