Installation Procedure
To install the 7371-K155 Hybrid Anti-Tipping Plate, follow these steps:
- Install one (1) Hybrid Anti-Tipping Bracket Mount to the rear of the Hybrid Stabilizer Plate, as shown in the image below. Secure the bracket using three (3) pan head screws.
- From the back of the unit, slide the Hybrid Stabilizer Plate through the bottom of the Core (Cabinet).Note
Adjust the leveling feet to easily slide the Hybrid Stabilizer Plate.
Drop all of the leveling feet until the holes of the Hybrid Anti-Tipping Bracket Mount are aligned with the corresponding holes on the Core (Cabinet) bracket.
- Secure the Hybrid Stabilizer Plate assembly to the cabinet bracket using three (3) flat head screws.
- Unlock and open the Cosmetic Door using a key.
- Secure the Hybrid Anti-Tipping Bracket Mount to the front of the Hybrid Stabilizer Plate using three (3) flat head screws, as shown in the image below.
- Secure the Hybrid Stabilizer Plate assembly to the front cabinet bracket using three (3) flat head screws, as shown in the image below.
- Install the Skirt panels on the sides of the Core (Cabinet). For more information, refer to 7371-K150 Core Cabinet Skirt (No-Bag).Note
The Side Skirt panels must be installed before the front and back skirt panels.
- Install the Hybrid Skirts on the front and back of the Core (Cabinet) by doing the following:Note
The Hybrid Skirt panels must be installed after the Core (Cabinet) Side Skirt panels.
- On the front of the Core (Cabinet), do the following:
- Attach the Hybrid Skirt panels to the skirt bracket by aligning the open slots in the skirt panel with the screw holes in the skirt bracket.
- Secure each skirt panel to the bracket using three (3) screws.
- Adjust the skirt panels so that each panel is flush with the floor.
- Tighten the screws to secure the skirts in place.
- On the back of the Core (Cabinet), do the following:
- Attach the Hybrid Skirt panels to the skirt bracket by aligning the open slots in the skirt panel with the screw holes in the skirt bracket.
- Secure each skirt panel to the bracket using three (3) screws.
- Adjust the skirt panels so that each panel is flush with the floor.
- Tighten the screws to secure the skirts in place.
- On the front of the Core (Cabinet), do the following: