Bar Codes – 1

The Bar Codes – 1 Parameter Programming Mode contains programming parameters for UPC/EAN bar codes. The default values are shown in the Red boxes and also in the Parameter Defaults section earlier in this chapter.

UPC/EAN

The UPC/EAN parameter controls reading UPC/EAN bar codes. Disable reading UPC/EAN bar codes by scanning the Hex 0 tag and enable reading by scanning the Hex 1 tag.

If reading UPC/EAN bar codes is disabled, there are no other entries allowed for this parameter. However, if reading UPC/EAN bar codes is enabled, the remaining parameters can be programmed.

Extend UPC-A to EAN-13

The Extend UPC-A to EAN-13 parameter determines whether to pad the tag data, changing 12-digit UPC tags to 13-Character EAN tags. The program does this by putting a zero (0) at the front of the tag data. Scan the Hex 0 tag to disable this option or the Hex 1 tag to enable it.

Extend UPC-E to UPC-A

The Extend UPC-E to UPC-A parameter determines whether to pad the tag data, changing 6 digit UPC tags to 12-digit UPC-A tags. Scan the Hex 0 tag to disable this option or the Hex 1 tag to enable it.

Periodical Codes

The Periodical Codes parameter controls the processing of Periodical Codes. Disable Periodical Codes by scanning the Hex 0 tag and enable them by scanning the Hex 1 tag.

If Periodical Codes is disabled, there are no other entries allowed for this parameter. Scanning the Hex 0 tag also causes the scanner to go back to the Programming Mode. However, if Add-On Bar Codes is enabled, the Add-On Code Length and Send Data parameters must also be programmed.

Periodical Code Extension

The Periodical Code Extension parameter has three selections: 2-digit Add-On only, 5-digit Add On only, and either 2- or 5-digit Add-Ons. Scan the Hex 0 tag for 2-digit only, the Hex 1 tag for 5-digit extension, or the Hex 2 tag for both the 2- and 5-digit.

Send Data

Send Data parameter has only one option: Data As Decoded. If the Hex 0 tag is scanned, the data is sent as decoded, whether or not there are extension digits.

Set 2 Tag Label

The Set 2 Tag Label parameter permits the scanner to read 2 tag specially-linked bar codes. This parameter has 2 selections: Enable and Disable. Scan Hex 2 to enable this function or scan Hex A tag to disable it.

Additional Functions

There are other functions associated with Bar Codes – 1 that are not included on the Programming Worksheet. Following are the programming sequences for these functions. Default values are shown in Blue type.

Convert UPC-E to EAN-13 Directly

UPC-E tags can be converted directly to EAN-13 tags. This function is only needed if UPC-A tags are not to be converted to EAN-13 tags.

Selection Programming Tag Sequence

Disable

Programming Mode, Hex 4, Hex 7, Hex 6, Save and Reset

Enable

Programming Mode, Hex 4, Hex 7, Hex 7, Save and Reset

Number of UPC/EAN Scans Required

This parameter sets the number of scans required to read a UPC or EAN bar code. Increasing the number of scans can improve reading nominal bar codes.

Selection Programming Tag Sequence

1 Scan

Programming Mode, Hex 6, Hex B, Hex 3, Hex 1, Save and Reset

2 Scans

Programming Mode, Hex 6, Hex B, Hex 3, Hex 2, Save and Reset

3 Scans

Programming Mode, Hex 6, Hex B, Hex 3, Hex 3, Save and Reset

4 Scans

Programming Mode, Hex 6, Hex B, Hex 3, Hex 4, Save and Reset

UPC NS5 Coupon

Selection Programming Tag Sequence

Enable

Programming Mode, Hex 7, Hex 1, Hex C, Save and Reset

Disable

Programming Mode, Hex 7, Hex 1, Hex D, Save and Reset

EAN-13 98 coupons

Selection Programming Tag Sequence

Enable

Programming Mode, Hex 7, Hex 1, Hex 8, Save and Reset

Disable

Programming Mode, Hex 7, Hex 1, Hex 9, Save and Reset

EAN-13 99 coupons

Selection Programming Tag Sequence

Enable

Programming Mode, Hex 7, Hex 1, Hex A, Save and Reset

Disable

Programming Mode, Hex 7, Hex 1, Hex B, Save and Reset