Advanced Data Formatting (ADF) Programming

ConditionBeeper IndicationSystem LED IndicationButton LED IndicationDescription
Number expectedHigh, Low BeepsGreenNo changeEnter another digit. Add leading zeros to the front if necessary.
Alpha character expectedLow, Low BeepsGreenNo changeEnter another alphabetic character or scan the End of Message bar code.
Criteria or action expectedHigh, High BeepsGreen BlinkingNo changeADF criteria or action is expected. Enter another criterion or action, or scan the Save Rule bar code.
ADF rule savedHigh, Low, High, Low BeepsGreen (turns off blinking)No changeRule saved. Rule entry mode exited.
Criteria or action clearedHigh, Low, Low BeepsGreenNo changeAll criteria or actions cleared for current rule, continue entering rule.
Last rule deletedLow BeepGreenNo changeDelete last saved rule. The current rule is left intact.
All rules deletedLow, High, High BeepsGreenNo changeAll rules are deleted.
ADF out of memoryLow, High, Low, High BeepsRedNo changeOut of rule memory. Erase some existing rules, then try to save rule again
Cancel rule entryLow, High, Low BeepsGreen (turns off blinking)No changeCancel rule entry. Rule entry mode exited because of an error or the user asked to exit rule entry.
Rule errorLow, High BeepsRedNo changeEntry error, wrong bar code scanned, or criteria/action list is too long for a rule. Re-enter criterion or action.