Button Presses

ConditionBeeper IndicationSystem LED IndicationButton LED IndicationDescription
Press and release Scale Zero buttonClickNo changeScale Zero button LED blinks green (momentary)LED illuminates only if Scale Zero button is enabled. Causes the scale to zero.
Press and hold Scale Zero buttonClickNo changeNoneIf Scale Zero button is enabled, causes the scale calibration audit trail to display until button is released.
Press and hold/release Scale Zero and EAS buttonsClickRed after 10 seconds upon rebootNo changeAfter buttons are held for 10 seconds, a system reboot initiates.
Press and hold Scale Zero and Volume/Tone buttons for 5 seconds, then releaseShort beep after 5 seconds; within 2 seconds of release, press the Scale Zero and Volume/Tone again and release; 5 long beeps soundNo changeNo changeAfter the final 5 long beeps sound, scale calibration is entered.
Press and release EAS buttonClickNo changeEAS is enabled, LED is amberIf EAS is enabled, button press activates tag manual deactivation.