Scale

Scale State7-segment Diagnostic DisplayLED (System)Beeper SequenceScale Zero Button (LED)Optional Scale Display
Scale disabledNo changeNo changeNoneOffBlank
Scale normal - stable with weightNo changeNo changeNone; single short beep after weight request from POS, if this feature is enabled.Solid Green OnWeight reading
Under zeroNo changeNo changeNoneFlashingAll “- - - - -” (dashes)
Over range condition (weight is greater than 30.09 lb or 15.045 kg)No changeNo changeNoneOffEEEEE
Weight unstableNo changeNo changeNoneOffNumerical values blank but measurement unit icons (lb or kg) remain on.
Scale Zero button pressIf zero operation fails, it scrolls U12Red (Warning) if zero operation fails on a Scale Zero button press; otherwise, no changeClick soundNo changeIf successful, weight reads 0 (zero) and <0> indicator icon illuminates.
Scale out of calibrationScrolls fault code U14Red (Warning)NoneOffBlinks CAL
Successfully entering scale legal Calibration Mode
  • At "Programming Legal Parameters" step or "Calibration at No Load" step, shows C00Lb or C00g, depending on the programmed unit of weight.
  • At "Calibration at Load" step, shows C25Lb or C10g, depending on the programmed unit of weight.
  • After "Calibration at No Load" and "Calibration at Load," repeatedly shows CAL P and CAL S.
  • If calibration fails at any step, shows error code u##.
No changeFive long beepsOff
  • At "Calibration at No Load" step, blinks between CAL00 and CAL_ _ with the correct unit icon illuminated (lb or kg).
  • At "Calibration at Load" step, blinks CAL25 with the lb icon illuminated, or blinks CAL10 with the kg icon illuminated.
  • After "Calibration at No Load" and "Calibration at Load," blinks between CAL P (PASS) and CAL S (save legal parameter settings).
  • If calibration fails at any step, blinks CAL F.
Between calibration stepsNo changeNo changeNo changeOffBlinks HOLD while taking a measurement.
Stepping through a calibration stepNo changeNo changeSingle long beep tone after pressing the Scale Zero buttonOffNo change
Failure to place the correct load on the scale at "Calibration at Load" stepC25Lb or C10g, depending on the programmed unit of weightNo changeTwo long beep tonesNo changeNo change
Successfully executing and exiting a scale legal calibrationCalibration procedure semantics removed from display.No changeThree short beepsSolid Green On if weight is stable after resetting the scaleScale is reset either by pressing the Scale Zero button, scanning the Scale Reset parameter bar code, of powering the unit Off then On again. The seven segment test will run.
Cold reset of scaleNo changeNo changeNo change except after "Calibration at No Load" and "Calibration at Load,". When the Scale Zero button is pressed during this step, three short beep tones is emitted.No change

Seven segment test runs and displays the following:

  • 00.000 all icons illuminated for three seconds
  • Blank for one second
  • 99.999 all icons illuminated for three seconds
  • Blank for one second
  • Normal display
Audit Tally - Press and hold Scale Zero button for greater than three seconds not in Calibration ModeRepeatedly scrolls C### then P###No changeNoneNo changeBlinks between C### and P###
In Bootloader ModeNo changeOffNoneOffNone
Scale ErrorScrolls fault code u##Red (Warning)NoneOff
  • Blinks FAIL or blanks display with unit icon showing lb or kg illuminated
  • Blinks CAL F if the system is in scale legal Calibration Mode.