Scale
Scale State | 7-segment Diagnostic Display | LED (System) | Beeper Sequence | Scale Zero Button (LED) | Optional Scale Display |
---|---|---|---|---|---|
Scale disabled | No change | No change | None | Off | Blank |
Scale normal - stable with weight | No change | No change | None; single short beep after weight request from POS, if this feature is enabled. | Solid Green On | Weight reading |
Under zero | No change | No change | None | Flashing | All “- - - - -” (dashes) |
Over range condition (weight is greater than 30.09 lb or 15.045 kg) | No change | No change | None | Off | EEEEE |
Weight unstable | No change | No change | None | Off | Numerical values blank but measurement unit icons (lb or kg) remain on. |
Scale Zero button press | If zero operation fails, it scrolls U12 | Red (Warning) if zero operation fails on a Scale Zero button press; otherwise, no change | Click sound | No change | If successful, weight reads 0 (zero) and <0> indicator icon illuminates. |
Scale out of calibration | Scrolls fault code U14 | Red (Warning) | None | Off | Blinks CAL |
Successfully entering scale legal Calibration Mode |
| No change | Five long beeps | Off |
|
Between calibration steps | No change | No change | No change | Off | Blinks HOLD while taking a measurement. |
Stepping through a calibration step | No change | No change | Single long beep tone after pressing the Scale Zero button | Off | No change |
Failure to place the correct load on the scale at "Calibration at Load" step | C25Lb or C10g, depending on the programmed unit of weight | No change | Two long beep tones | No change | No change |
Successfully executing and exiting a scale legal calibration | Calibration procedure semantics removed from display. | No change | Three short beeps | Solid Green On if weight is stable after resetting the scale | Scale is reset either by pressing the Scale Zero button, scanning the Scale Reset parameter bar code, of powering the unit Off then On again. The seven segment test will run. |
Cold reset of scale | No change | No change | No change except after "Calibration at No Load" and "Calibration at Load,". When the Scale Zero button is pressed during this step, three short beep tones is emitted. | No change | Seven segment test runs and displays the following:
|
Audit Tally - Press and hold Scale Zero button for greater than three seconds not in Calibration Mode | Repeatedly scrolls C### then P### | No change | None | No change | Blinks between C### and P### |
In Bootloader Mode | No change | Off | None | Off | None |
Scale Error | Scrolls fault code u## | Red (Warning) | None | Off |
|